Products > HT-S-3000
1) Pure sine wave output (<2% THD).
2) Input & Output fully isolation design.
3) High efficiency 87%~90%.
4) Internal and external heat sinks.
5) Multi-stage thermal control fan.
6) Frequency 50/60Hz selective switch.
7) Re-start function.
8) Complete protection design.
9) Green power function.
10) Movable front LCD display panel.
11) APP display – option.
12) Bypass function – optional.
13) Hard wiring design.
2) Input & Output fully isolation design.
3) High efficiency 87%~90%.
4) Internal and external heat sinks.
5) Multi-stage thermal control fan.
6) Frequency 50/60Hz selective switch.
7) Re-start function.
8) Complete protection design.
9) Green power function.
10) Movable front LCD display panel.
11) APP display – option.
12) Bypass function – optional.
13) Hard wiring design.
HT-S-3000 Datasheet
HT-S-3000 Manual
Model No. | HT-S-3000-12 | HT-S-3000-24 | HT-S-3000-48 |
OUTPUT | |||
AC Voltage | 100VAC / 120VAC / 230VAC | ||
Continuous Power | 3000W | ||
Surge Power | 6000W | ||
Waveform | Pure Sine Wave | ||
Frequency | 50/60Hz±3% | ||
AC Regulation | ±8%(100V:±10%) | ||
Receptacles | 1pc | ||
INTPUT | |||
DC Current | 300A | 150A | 75A |
DC nol oad current normal mode. | 1.0A | 0.5A | 0.25A |
DC no load current under power saving mode. | 0.12A | 0.06A | 0.03A |
DC Voltage | 12V | 24V | 48V |
Voltage Range | 10-16VDC | 20-32VDC | 40-61VDC |
Efficiency (Typ.) | >85% | ||
DC Connector | cable*1pc | ||
Fuse | 15pcs. | ||
PROTECTION | |||
Battery low alarm | 10.5±0.5V | 21±1V | 42±2V |
Battery low shut down | 10±0.5V | 20±1V | 40±2V |
Over voltage | 16±0.5V | 32±1V | 61±2V |
Over Temperature | 55℃±5℃ | ||
Short Circuit Protection | Shut-off | ||
Battery polarity | Fuse Burn out | ||
Over Load | Re-start 1 time, shut down if failed | ||
ENVIRONMENT | |||
Working Temp. | -15℃~ +45℃ | ||
Working Humidity | 20%~90% RH non-condensing | ||
Storage Temp., Humidity | -30℃~ +70℃/ -22℉~ +158℉, 10~95% RH | ||
Temp. Coefficient | ±0.05% ℃ (0~55℃) | ||
SAFETY | |||
EMI Conduction & Radiation | Compliance to EN55022 class B, 72/245/CEE, 95/54/CE | ||
EMS Immunity | Compliance to EN61000-4-2, 3 | ||
LVD | Compliance to EN60905 | UL | UL458 |
OTHERS | |||
Dimension (LxWxH) | 570x274x105 mm | ||
Net. Weight | 9.8 kgs | ||
Gross Weight (With Cable) | 10.8 kgs | ||
Optional | |||
EXTERA FUNTION | |||
Bypass function | Yes | ||
INPUT | |||
DC no load current under normal mode. | 1.0A | 0.5A | 0.25A |
DC no load current under power saving mode. | 0.4A | 0.2A | 0.1A |
INVERTER | |||
Low AC input volt transfer to inverter mode. | 90Vac±5% or 180Vac±5% | ||
Low AC input volt recovery to AC mode. | 95Vac±5% or 190Vac±5% | ||
High AC input voit transfer to inverter mode. | 132Vac±5% or 265Vac±5% | ||
High AC input volt recoveryto AC mode. | 125Vac±5% or 250Vac±5% | ||
CONNECTOR | |||
Iput AC terminal | Yes, hard wiring | ||
Output AC terminal | Yes, hard wiring | ||
Receptacles | No |